TTX 110 Core Thermometer Thermocouple Type T

Thermocouple thermometer with fixed probe

• Fast measurements, high accuracy
• HACCP
• Robust and impact resistant
• Replaceable battery
Product number: 1340-5110
Weight
approx. 40 g
Accuracy
± 0.8 °C or ± 0.8 % whichever is greater
Protection class
IP55
Dimensions
90 x 42 x 17 mm
Resolution
0.1 °C from -60 °C...+199 °C otherwise 1°C
Certificate
Factory calibration certificate
Measured variables
temperature
Battery
Lithium 3 V , type CR 2450
Measuring range
-50 °C...+350 °C
Storage temperature
-30 °C...+70 °C
  • ISO Calibration for handhelds at 3 standard temperature point of product series: 
    TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.

    Product number:: 1030-2403
  • ISO Calibration for handhelds at 4 standard temperature point of product series: 
    TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.

    Product number:: 1030-2404
  • ISO Calibration for handhelds at 5 standard temperature point of product series:
    TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.

    Product number:: 1030-2405
  • ISO Calibration for handhelds at 6 standard temperature point of product series: 
    TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.

    Product number:: 1030-2406
  • ISO Calibration for handhelds at 7 standard temperature point of product series: 
    TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.

    Product number:: 1030-2407
  • ISO Calibration for handhelds at 8 standard temperature point of product series: 
    TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.

    Product number:: 1030-2408
  • Accredited calibration according to DAkkS guidelinesfor handhelds at three points of product series: 
    TFX, TFE, TFN, TLC, GFX, TTX, TFH.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.  
    Product number:: 1030-3403
  • Accredited calibration according to DAkkS guidelines for handhelds at four points.
    Calibration service for handhelds of product series: TFX, TFE, TFN, TLC, GFX, TTX, TFH.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.

    Product number:: 1030-3404
  • Accredited calibration according to DAkkS guidelines for handhelds at five points of product series: 
    TFX, TFE, TFN, TLC, GFX, TTX, TFH.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.

    Product number:: 1030-3405
  • Accredited calibration according to DAkkS guidelinesfor handhelds at six points.
    Calibration service for handhelds of product series: TFX, TFE, TFN, TLC, GFX, TTX, TFH.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.

    Product number:: 1030-3406
  • Accredited calibration according to DAkkS guidelines for handhelds at seven points.
    Calibration service for handhelds of product series: TFX, TFE, TFN, TLC, GFX, TTX, TFH
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025

    Product number:: 1030-3407
  • Accredited calibration according to DAkkS guidelines for handhelds at eight points. 
    Calibration service for handhelds of product series: TFX, TFE, TFN, TLC, GFX, TTX, TFH
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025

    Product number:: 1030-3408
  • Punching pin for drilling hole in deep-frozen food to take core temperature reading
    Product number:: 1341-3834