EBI 12-T221 Validation logger for hot air use

Product number: 1340-6605

Measurement up to +400 °C

With this data logger, temperatures above +150 °C, which are typically present in hot air sterilization, can be measured. The data logger itself requires additional temperature protection, the TIB box. For this purpose, you will find the TIB2 temperature protection box in the accessories.

Benefits:

  • large measuring range
  • wireless measurement
  • Realtime data transmission
  • fast response time
  • bendable metal probe

Applications:
  • Validation logger for temperature measurement in the steam sterilizer, WD and endoscope washer
  • Validation in the hot air sterilizer
  • A0 Value calculation
  • F0 Value calculation
  • Validation of baking processes

Datasheet


NEW: Information package "Professional data loggers"

You still need a more comprehensive overview of the possibilities and requirements of the data logger, references to the service, certificates or the suitable software? Then read the comprehensive information package for the food sector or the medical/pharmaceutical sector here.
Go to information package
Data memory
100,320 measurement values
Sensor
Pt 1,000, class A
Weight
approx. 110 g
Accuracy
± 1,5 °C (-200 °C … -85 °C) ± 0,5°C (-85 °C … -40 °C) ± 0,2°C (-40 °C … 0 °C) ± 0,1 °C (0 °C ... +120 °C) ± 0,05 °C (+120 °C … +140 °C) ± 0,1 °C (+140 °C … +150 °C) ± 0,5 °C (+150 °C …+ 250 °C) ± 0,8 °C (+250 °C … +400 °C)
Protection class
IP68
Dimensions
(Ø x H) 48 mm x 24 mm, Needle length 500 mm
Resolution
0,01 °C
Certificate
Factory Calibration: -20 °C, 0 °C, +60 °C, +134 °C and +250 °C
Measured variables
Temperature
Intervall
250 msec ... 24 h
Measuring range
-200 °C ... +400 °C
Storage temperature
-20 °C ... +70 °C
  • • Developed for real time monitoring
    • AL 112 is a cable with 3 m length
    • Antenna placement in the field of the door seal of a sterilizer or washer disinfector
    • Antenna steam-tight
    • It is possible by a sealing to introduce it in the chamber
    Product number: 1340-6007
  • • Usable from +150 °C ... +400 °C
    • Thermal protection of data loggers
    • Stainless steel
    Product number: 1340-1892
  • For securing the EBI 12 data loggers in process you need the AL 121 opening tool.
    Product number: 1248-0122
  • AL 285 Logger Check In combination with the software Winlog.validation version >= 3.62 the AL 285 offers you a simple, on site functional check of the measuring channels.
    Product number: 1248-0285
  • 4-port Interface IF 200
    Software Winlog.validation
    USB connection
    Colored LEDs signaling programming, readout and incorrect development
    Includes antenna

    Product number: 1340-6068
  • 4-port Interface IF 200
    Software Winlog.pro
    USB connection
    Colored LEDs signaling programming,readout and incorrect development
    Includes antenna

    Product number: 1340-6062
  • USB-connector
    Colored LED signals programming,
    readout and faulty execution
    Including Antenna AL 111
    Software Winlog.med

    Product number: 1340-6095
  • opening tool for EBI 12

    Product number: 1100-0131
  • Consisting of 3 batteries, 6 O-rings with grease and opening tool EBI 12
    Product number: 1100-0130
  • For EBI 12 + EBI 16 Consisting of 3 batteries, 6 O-rings with grease.
    Product number: 1100-0118
  • ISO Calibration for temperature- validation- and process logger at 5 standard points of the following product series: EBI 12, EBI 11, EBI 10, EBI 100.

    Product number: 1030-2205
  • Accredited calibration according to DAkkS guidelines for temperature- validation- and process logger at three points. Calibration service for data logger of the following product series:
    EBI 12, EBI 11, EBI 10, EBI 100.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.
    Product number: 1030-3203
  • Accredited calibration according to DAkkS guidelines for temperature- validation- and process logger at four points of the following product series: EBI 12, EBI 11, EBI 10, EBI 100.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.
    Product number: 1030-3204
  • Accredited calibration according to DAkkS guidelines for temperature- validation- and process logger at five points of the following product series: EBI 12, EBI 11, EBI 10, EBI 100.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.
    Product number: 1030-3205
  • Accredited calibration according to DAkkS guidelines for temperature- validation- and process logger at six points of the following product series: EBI 12, EBI 11, EBI 10, EBI 100.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.
    Product number: 1030-3206
ISO 17665 Sterilization of health care products — Moist heat
ISO 15883 Washer Disinfectors
2014/53/EU Radio Equipment Directive - RED
(EC) 1935/2004 Materials and articles which come into contact with foodstuffs

NEW: Information package "Professional data loggers"

Please fill out the form below and the download will start instantly.
Zertifikate