TFH 610 Hygrothermometer
Product number:
1340-5610
with fixed humidity probe
- Robust and impact resistant
- High accuracy
- °C/°F selectable
- Approximately 5 years battery life time
- Automatic deactivation
- Sensor
- Kapazitiv / Thermistor
- Weight
- approx. 90g
- Accuracy
- Humidity at 10...90% rH ±2.5 % rH Temperature: ±0.5 °C
- Protection class
- IP40
- Dimensions
- 115 x 54 x 22 mm
- Resolution
- Humidity: 0.1 % rH Temperature: 0.1 °C
- Certificate
- Factory calibration certificate
- Measured variables
- temperature, humidity
- Intervall
- 1-15 sec.
- Battery
- Lithium button cell 3.0 V/1000 mAh
- Measuring range
- Humidity: 0 to 100 % rH Temperature: 0 °C to +50 °C
- Storage temperature
- -25 °C...+60 °C
-
The stainless steel sintered filter AH 300 also increases the protection class to IP 40. The stainless steel massively increases the mechanical protection, e.g. from crushing the filter. Nothing will happen to your probe! In addition, the stainless steel is highly resistant to corrosion even in high temperature applications.Product number: 1340-5625
-
Battery exchange set
Consisting of: Battery 3V Lithium CR 2477, Needle, Screws, Plugs, O-Ring and InstructionsProduct number: 1100-0106 -
The PTFE-filter AH 100 provides little protection from mechanical strain but seals the probe from dust – protection class IP 60. In dusty environments, unprotected humidity probes, or probes protected by sintered fi lters, can quickly be covered by dust. This massively affects the humidity measurement, or prohibits it entirely. It won´t happen with the PTFE filter.Product number: 1340-5627
-
Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 5 calibration points, in a temperature range of -90 °C ... +250 °C.Product number: 1030-3405
-
Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 4 calibration points, in a temperature range of -90 °C ... +250 °C.Product number: 1030-3404
-
Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 3 calibration points, in a temperature range of -90 °C ... +250 °C.
Product number: 1030-3403 -
Calibration for handhelds of the following products: CT 830, FOM 330 series, PHT 810, PHT 830, TDC 110, TDC 150, TDC 200, TFH 610, TFI 54, TFI 500 ohne Fühler, TFI 550 ohne Fühler, TFI 650 ohne Fühler, TLC 700, TLC 720, TLC 730, TLC 750, VAM 320 Consisting of ISO calibration at 2 standard points that are defined by us. (according to ISO 9001)Product number: 1030-2402
-
Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 2 calibration points, in a temperature range of -90 °C ... +250 °C.
Product number: 1030-3402