TFX 420 + TPX200 Precision Core Thermometer

Product number: 1340-5428

with MIN/MAX and hold options

• Large, easy-to read display
• Robust and impact-resistant
• Different probes available
• High accuracy
• Waterproof
• Exchangeable battery
• Factory calibration certificate
Sensor
Pt 1000
Accuracy
±0,3 °C / ±0,5 °F; device with probe and factory calibration
Protection class
IP67
Resolution
0,1 °C
Certificate
3-point Factory calibration certificate
Measured variables
Temperature
Battery
3.0 V lithium battery exchangeable
Measuring range
-50 °C..+400 °C
Storage temperature
-30 °C...+70 °C
  • Calibration for handhelds of the following products: GFX 460 series, TFE 510 series with probe, TFH 620 + TPH 100, TFN 5x0 series with probe, TFX 410 series, TFX 420 series, TLC 1598 Consisting of ISO calibration at 3 standard temperature points that are defined by us. (according to ISO 9001)

    Product number: 1030-2403
  • Calibration for handhelds of the following products: TDC 100, TFI 250, TFI 260, TTX series Consisting of ISO calibration at 1 standard temperature point that are defined by us. (according to ISO 9001)
    Product number: 1030-2401
  • Calibration for handhelds of the following products: CT 830, FOM 330 series, PHT 810, PHT 830, TDC 110, TDC 150, TDC 200, TFH 610, TFI 54, TFI 500 ohne Fühler, TFI 550 ohne Fühler, TFI 650 ohne Fühler, TLC 700, TLC 720, TLC 730, TLC 750, VAM 320 Consisting of ISO calibration at 2 standard points that are defined by us. (according to ISO 9001)
    Product number: 1030-2402
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 2 calibration points, in a temperature range of -90 °C ... +250 °C. 
    Product number: 1030-3402
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 1 calibration point, in a temperature range of -90 °C ... +250 °C.
    Product number: 1030-3401
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 3 calibration points, in a temperature range of -90 °C ... +250 °C.
    Product number: 1030-3403
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 4 calibration points, in a temperature range of -90 °C ... +250 °C. 

    Product number: 1030-3404
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 5 calibration points, in a temperature range of -90 °C ... +250 °C.
    Product number: 1030-3405
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 6 calibration points, in a temperature range of -90 °C ... +250 °C.

    Product number: 1030-3406
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 7 calibration points, in a temperature range of -90 °C ... +250 °C.

    Product number: 1030-3407
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 8 calibration points, in a temperature range of -90 °C ... +250 °C.
    Product number: 1030-3408
  • Punching pin for drilling hole in deep-frozen food to take core temperature reading
    Product number: 1341-3834
  • Stainless steel bracket for TFX-Thermometer
    Product number: 1340-0595
  • Protective cover for thermometer, red
    Product number: 1340-5005
  • Battery exchange set 
    Consisting of:  Battery 3V Lithium CR 2477,  Needle, Screws,  Plugs,  O-Ring and Instructions
    Product number: 1100-0106
  • Silicone extension cable for TFX units, 1m, Lemosa size 0
    Product number: 1340-5015
  • TPX 400-40 Pt 1000 probe for TFX 410-1 / 420 Thermometer, pointed probe
    Product number: 1341-4164
  • TPX 440 Pt 1000 probe for TFX 410-1 / 420 Thermometer, pointed probe
    Product number: 1341-4169
  • TPX 200-30 Pt 1000 probe for TFX 410-1 / 420 Thermometer
    Product number: 1341-4183
  • Probe for TFX 410/420, pointed probe
    Product number: 1341-5418
  • Wall bracket with 6 clips, plastic, for thermometer TFX
    Product number: 1340-5000
  • TPX 400 Pt 1000 probe for TFX 410-1 / 420 Thermometer
    Product number: 1341-5416
  • Stainless steel bracket for thermometer TFN
    Product number: 1340-0596
  • Large case for TFN devices and several large sensors 
    (without device and accessories) 
    Product number: 1341-3857
  • Aluminum case (small) for TFN-instruments
    Product number: 1341-3854
  • TPX 400-150 Pt 1000 probe for TFX 410-1 / 420 Thermometer, pointed probe
    Product number: 1341-4168
  • TPX 200-20 Pt 1000 probe for TFX 410-1 / 420 thermometer, pointed probe
    Product number: 1341-4182
  • TPX 200-40 Pt 1000 probe for TFX 410-1 / 420 Thermometer
    Product number: 1341-4184
  • Pt 1000 probe for TFX 410-1 / 420 thermometer 
    Product number: 1341-5419