TTX 210 Type T Core Thermometer without a probe

Product number: 1340-5151

for changeable probes

Without probe please order separately.
The TTX 210 enhances the benefits of the TTX 200 by the flexibility of several changeable probes. As required, a rigid probe for measurement in fluids or semisolid material, or a probe with grip can be used. The latter is available with two different cable lengths. Apart from serving different applications, this allows for easy replacement of a defective probe.
Very large display with big numbers for easy reading

  • Compliant to DIN EN 13485 and HACCP
  • Very big display for easy reading
  • Changeable probes, can be purchased separately
  • Easy to use
  • Changeable batteries
  • Watertight housing (IP 65)

Weight
aprox. 100 g
Accuracy
+25 °C ±0,5 °C, -30 °C ...+100 °C
Protection class
IP65
Dimensions
127 x 60 x 16 mm without probe
Resolution
0,1 °C 
Certificate
Factory calibration certificate
Measured variables
Temperature
Battery
CR 2032, replaceable
Measuring range
-30 °C ... +199,9 °C
Storage temperature
-30 °C ... +70 °C
  • TPE 100 pointed probe for TTX 210 Type T Core Thermometer , NL = 120 mm, Ø 3 mm 
    Product number: 1341-5152
  • TPE 200 Pointed probe for TTX 210 Type T Core Thermometer
    NL = 120 mm, Ø 3 mm, 60 cm silicone cable, grip 
    Product number: 1341-5153
  • TPE 200-150 Pointed probe for TTX 210 Type T Core Thermometer 
    NL = 120 mm, Ø 3 mm, 150 cm silicone cable, grip 
    Product number: 1341-5154
  • Punching pin for drilling hole in deep-frozen food to take core temperature reading
    Product number: 1341-3834
  • Battery Lithium for EBI 20/ EBI 300/ 310

    Product number: 1100-0105
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 3 calibration points, in a temperature range of -90 °C ... +250 °C.
    Product number: 1030-3403
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 1 calibration point, in a temperature range of -90 °C ... +250 °C.
    Product number: 1030-3401
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 2 calibration points, in a temperature range of -90 °C ... +250 °C. 
    Product number: 1030-3402
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 4 calibration points, in a temperature range of -90 °C ... +250 °C. 

    Product number: 1030-3404
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 5 calibration points, in a temperature range of -90 °C ... +250 °C.
    Product number: 1030-3405
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 6 calibration points, in a temperature range of -90 °C ... +250 °C.

    Product number: 1030-3406
  • Calibration for handhelds of the following products: CT 830, FOM 330 series, PHT 810, PHT 830, TDC 110, TDC 150, TDC 200, TFH 610, TFI 54, TFI 500 ohne Fühler, TFI 550 ohne Fühler, TFI 650 ohne Fühler, TLC 700, TLC 720, TLC 730, TLC 750, VAM 320 Consisting of ISO calibration at 2 standard points that are defined by us. (according to ISO 9001)
    Product number: 1030-2402