Mini validation pressure logger EBI 11-P111

Mini validation pressure data logger to messure in steam sterilizers and Washer disinfectors.

• Gran exactitud
• Totalmente impermeable
• Carcasa de metal alimentario PEEK
• Pequeñas dimensiones
• No se necesitan conductos
• Batería cambiable sobre el usario
Número de producto: 1340-6296
Capacidad de almacenamiento
2 x 7.500 valores
Sensor
Pt 1000
Pesa
aprox. 45 g
Precisión
± 15 mbar (0 mbar...4000 mbar ) ± 20 mbar (4000 mbar...10000 mbar)
Clase de protección
IP68
Dimensiones
ø 16,5 mm x 47 mm
Resolución
1 mbar
Certificado
Certificado de calibración de fábrica
Variables medidas
Pression
Intervalo de medida
1s...24h
Batería
2 x 3V
Campo de medición
1 mbar...10.000 mbar
Temperatura de almacenamiento
-20 °C...+70 °C
  • • Conexión USB
    • Señal en color del LED que indica el estado
      (Programa, lectura, error)
    • TÜV certified Software Winlog.validation
    Número de producto:: 1340-6069
  • • Conexión USB
    • Señal en color del LED que indica el estado
      (Programa, lectura, error)
    • Software Winlog.med
    Número de producto:: 1340-6064
  • Suitable for 10 battery exchanges; contains 20 batteries, 10 O-rings with grease and changing tools.
    Número de producto:: 1100-0125
  • El paquete de cambio de baterías se contiene: 6 baterías, 1 atornillador de tornillo Phillips, 3 juntas tóricas lubricadas
    Número de producto:: 1100-0120
  • ISO Calibration for pressure- temperature data logger, humidity- and conductivity data logger at 3 standard temperature points and the calibration of the additional measurand of the following product series: EBI 12, EBI 11, EBI 10, EBI 100.

    Número de producto:: 1030-2223
  • Accredited calibration according to DAkkS guidelines for pressure- temperature data logger, humidity- and conductivity data logger at three temperature points of the following product series: EBI 12, EBI 11, EBI 10, EBI 100.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.
    Número de producto:: 1030-3223
  • Accredited calibration according to DAkkS guidelines for pressure- temperature data logger, humidity- and conductivity data logger at four temperature points of the following product series: EBI 12, EBI 11, EBI 10, EBI 100.
    Consisting of an accedited calibration according to DIN EN ISO / IEC 17025.
    Número de producto:: 1030-3224
  • Accredited calibration according to DAkkS guidelines for pressure- temperature data logger, humidity- and conductivity data logger at five temperature points. 
    Calibration service for pressure- temperature data logger of the following product series: 
    EBI 12, EBI 11, EBI 10, EBI 100
    Consisting of an accedited calibration according to DIN EN ISO / IEC 17025. 
    Número de producto:: 1030-3225
  • Accredited calibration according to DAkkS guidelines for pressure- temperature data logger, humidity- and conductivity data logger at six temperature points of the following product series: EBI 12, EBI 11, EBI 10, EBI 100.
    Consisting of an accedited calibration according to DIN EN ISO / IEC 17025.
    Número de producto:: 1030-3226
ISO 17665 Sterilization of health care products — Moist heat
ISO 15883 Washer Disinfectors
• (CE) N° 1935/2004 Materiales y objetos que entran en contacto con los alimentos
2014/30/EU The EMC Directive 2014/30/EU regulates the electromagnetic compatibility    
  of equipment