TFE 510 + TPE 400 Termómetro

Número de producto: 1340-5516

with fast response time

  • Muy rápido
  • Gran exactitud
  • Gran pantalla
  • Robusto y a prueba de golpes
  • Duración de la batería aprox. 5 años
  • Visualización del estado de la batería
  • Impermeable IP 67
  • Conmutable a °C/°F
Sensor
Thermoelement, Typ T
Pesa
approx. 90 g
Precisión
± 0,5 °C
Clase de protección
IP67
Dimensiones
109 x 54 x 22 mm
Resolución
0,1 °C
Certificado
Certificado de calibración de fábrica
Variables medidas
temperatura
Batería
Lithium 3 V
Campo de medición
-50 °C...300 °C
Temperatura de almacenamiento
-30 °C...+70 °C
  • Calibration for handhelds of the following products: GFX 460 series, TFE 510 series with probe, TFH 620 + TPH 100, TFN 5x0 series with probe, TFX 410 series, TFX 420 series, TLC 1598 Consisting of ISO calibration at 3 standard temperature points that are defined by us. (according to ISO 9001)
    Número de producto: 1030-2403
  • Calibration for handhelds of the following products: CT 830, FOM 330 series, PHT 810, PHT 830, TDC 110, TDC 150, TDC 200, TFH 610, TFI 54, TFI 500 ohne Fühler, TFI 550 ohne Fühler, TFI 650 ohne Fühler, TLC 700, TLC 720, TLC 730, TLC 750, VAM 320 Consisting of ISO calibration at 2 standard points that are defined by us. (according to ISO 9001)
    Número de producto: 1030-2402
  • Calibration for handhelds of the following products: TDC 100, TFI 250, TFI 260, TTX series Consisting of ISO calibration at 1 standard temperature point that are defined by us. (according to ISO 9001)
    Número de producto: 1030-2401
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 2 calibration points, in a temperature range of -90 °C ... +250 °C. 
    Número de producto: 1030-3402
  • Accredited Calibration Service 1030-3403 for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 3 calibration points, in a temperature range of -90 °C ... +250 °C.
    Número de producto: 1030-3403
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 1 calibration point, in a temperature range of -90 °C ... +250 °C.
    Número de producto: 1030-3401
  • Calibración acreditada 1030-3404 for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 4 calibration points, in a temperature range of -90 °C ... +250 °C. 
    Número de producto: 1030-3404
  • Servicio de calibración 1030-3405 
    Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 5 calibration points, in a temperature range of -90 °C ... +250 °C.
    Número de producto: 1030-3405
  • Calibración acreditada 1030-3406 
    Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 6 calibration points, in a temperature range of -90 °C ... +250 °C.
    Número de producto: 1030-3406
  • Calibración acreditada 1030-3407 
    Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 7 calibration points, in a temperature range of -90 °C ... +250 °C.
    Número de producto: 1030-3407
  • Servicio de calibración 1030-3408 
    Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 8 calibration points, in a temperature range of -90 °C ... +250 °C.
    Número de producto: 1030-3408
  • Soporte de acero inoxidable para termómetro TFX
    Número de producto: 1340-0595
  • Funda protectora, rojo 
    Número de producto: 1340-5005
  • Stainless steel bracket for thermometer TFN
    Número de producto: 1340-0596
  • Pre-perforación para alimentos congelados (para medir la temperatura central)
    Número de producto: 1341-3834
  • Sonda de refacción TFE 510
    Número de producto: 1341-5516
  • Soporte de pared con 6 abrazaderas de pared, soporte de plástico para termómetro TFX
    Número de producto: 1340-5000
  • Juego de sustitución de baterías
    Consta de: pila de litio CR 2477 de 3V, aguja, tornillos, tapón, junta tórica e instrucciones
    Número de producto: 1100-0106
  • Cable alargador de silicona para las unidades TFX, 1m, Lemosa tamaño 0
    Número de producto: 1340-5015
  • Maleta grande para unidades TFN y varias sondas (sin unidad ni accesorios)
    Número de producto: 1341-3857
  • Aluminum case (small) for TFN-instruments
    Número de producto: 1341-3854