GFX 460 Thermomètre à Contact Electronique

avec sonde Pt 1000 fi xe, en acier inoxydable

• Réglage Fuzzy
• Boucle de réglage et de sécurité selon DIN EN 12878 classe 1 et 2
• Rétroéclairage de l’affichage vert
Product number: 1340-5460
Poids
env. 150g
Précision
± 1 °C
Type de protection
IP65
Dimensions
54x22x110 mm sans sonde
Résolution
1 °C
Grandeurs de mesure
Température
Intervalle de mesure
1s
Pile
extern 9-12V DC, 20 mA
Plage de mesure
-50 °C...+300 °C
Témperature de stockage
-30 °C...+70 °C
  • Suspension pour trépied avec 6 bornes, plastique
    Product number:: 1340-5001
  • Boîtier relais pour thermomètre électronique à contact GFX 460
    Product number:: 1340-0157
  • Extenstion cable 1m silicone for TFX 430 - instruments (LEMO Size 1)
    Product number:: 1340-5020
  • Calibration service for handhelds of product series:
    TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM
    Consisting of ISO calibration at 3 standard temperature point.
    Product number:: 1030-2403
  • ISO Calibration for handhelds at 4 standard temperature point of product series: 
    TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.

    Product number:: 1030-2404
  • ISO Calibration for handhelds at 5 standard temperature point of product series:
    TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.

    Product number:: 1030-2405
  • ISO Calibration for handhelds at 6 standard temperature point of product series: 
    TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.

    Product number:: 1030-2406
  • ISO Calibration for handhelds at 7 standard temperature point of product series: 
    TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.

    Product number:: 1030-2407
  • ISO Calibration for handhelds at 8 standard temperature point of product series: 
    TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.

    Product number:: 1030-2408
  • Accredited calibration according to DAkkS guidelinesfor handhelds at three points of product series:
    TFX, TFE, TFN, TLC, GFX, TTX, TFH.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.  
    Product number:: 1030-3403
  • Accredited calibration according to DAkkS guidelines for handhelds at four points.
    Calibration service for handhelds of product series: TFX, TFE, TFN, TLC, GFX, TTX, TFH.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.

    Product number:: 1030-3404
  • Accredited calibration according to DAkkS guidelines for handhelds at five points of product series: 
    TFX, TFE, TFN, TLC, GFX, TTX, TFH.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.

    Product number:: 1030-3405
  • Accredited calibration according to DAkkS guidelinesfor handhelds at six points.
    Calibration service for handhelds of product series: TFX, TFE, TFN, TLC, GFX, TTX, TFH.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.

    Product number:: 1030-3406
  • Accredited calibration according to DAkkS guidelines for handhelds at seven points.
    Calibration service for handhelds of product series: TFX, TFE, TFN, TLC, GFX, TTX, TFH
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025

    Product number:: 1030-3407
  • Accredited calibration according to DAkkS guidelines for handhelds at eight points. 
    Calibration service for handhelds of product series: TFX, TFE, TFN, TLC, GFX, TTX, TFH
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025

    Product number:: 1030-3408