FOM 330 BT Appareil de mesure radio de la qualité de l'huile
avec une lampe de signal
The FOM 330 BT Radio Food Oil Monitor has the same features as the FOM 330-
4 Food Oil Monitor. It can do much more, though. The FOM 330 BT has a memory
capacity for up to 200 measurement values. Thus you can measure in multiple fryers
directly one after another. The measurement values are saved and then can be
transferred e.g. to a PC at once– no manual notes required any more!
Unlike the standard device the FOM 330 BT has a rechargeable battery, which can be
charged either via the USB-C interface or wirelessly. You need a device supporting the
Qi standard in order to do the latter.
Thanks to the Bluetooth interface, the data can be transferred wirelessly e.g. to an app
on a mobile device. Usually the data is forwarded from there to a cloud based software,
where it is saved and evaluated.
- Wireless data transmission via Bluetooth Low Energy
- Wireless rechargeable battery
FOM 330 in 8 Steps download
Learn more about the time-saving solution for your
HACCP tasks! Download HACCP brochure
- Poids
- Env. 250 g
- Précision
- ± 1 °C ± 2 %
- Type de protection
- IP67
- Dimensions
- 314 x 54 x 22 mm
- Résolution
- 0,1 °C 0,5 %
- Certificat
- Certificat d'etallonage d'usine
- Grandeurs de mesure
- Témperature, TPM (total polar materials)
- Pile
- 3,7V lithium, remplaçable
- Plage de mesure
- +50 °C...200 °C 0%...40%
-
Calibration for handhelds of the following products: GFX 460 series, TFE 510 series with probe, TFH 620 + TPH 100, TFN 5x0 series with probe, TFX 410 series, TFX 420 series, TLC 1598 Consisting of ISO calibration at 3 standard temperature points that are defined by us. (according to ISO 9001)
Réf. produit : 1030-2403 -
Calibration for handhelds of the following products: TDC 100, TFI 250, TFI 260, TTX series Consisting of ISO calibration at 1 standard temperature point that are defined by us. (according to ISO 9001)
Réf. produit : 1030-2401 -
Calibration for handhelds of the following products: CT 830, FOM 330 series, PHT 810, PHT 830, TDC 110, TDC 150, TDC 200, TFH 610, TFI 54, TFI 500 ohne Fühler, TFI 550 ohne Fühler, TFI 650 ohne Fühler, TLC 700, TLC 720, TLC 730, TLC 750, VAM 320 Consisting of ISO calibration at 2 standard points that are defined by us. (according to ISO 9001)
Réf. produit : 1030-2402 -
Calibration for handhelds of the following products: TFN 5x0 series without probe, TFX 430 with probe Consisting of ISO calibration at 4 standard temperature points that are defined by us. (according to ISO 9001)Réf. produit : 1030-2404
-
Service d'étalonnage pour les appareils de mesure portables des produits suivants : TFX 430 sans sonde Comprenant l'étalonnage ISO sur cinq points standard définis par nos soins (selon ISO 9001)Réf. produit : 1030-2405