TDC 150 Thermometer

Product number: 1340-1611

with fast response time

Standard core thermometer for food temperature control.

  • Approx. 5,000 hours battery life.
  • Waterproof housing (IP65)
  • Needle protection included

Sensor
NTC
Weight
approx. 36 g
Accuracy
± 0,8 °C (-20 ° ...+120 °C)
Protection class
IP65
Dimensions
24 x 26 x 85 mm
Resolution
0.1 °C / -20 °C...+150 °C
Measured variables
temperature
Battery
1,5V, LR44m G13
Measuring range
-50 °C...+150 °C
Storage temperature
-10 °C...+60 °C
  • Punching pin for drilling hole in deep-frozen food to take core temperature reading
    Product number: 1341-3834
  • Calibration for handhelds of the following products: CT 830, FOM 330 series, PHT 810, PHT 830, TDC 110, TDC 150, TDC 200, TFH 610, TFI 54, TFI 500 ohne Fühler, TFI 550 ohne Fühler, TFI 650 ohne Fühler, TLC 700, TLC 720, TLC 730, TLC 750, VAM 320 Consisting of ISO calibration at 2 standard points that are defined by us. (according to ISO 9001)
    Product number: 1030-2402
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 2 calibration points, in a temperature range of -90 °C ... +250 °C. 
    Product number: 1030-3402
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 3 calibration points, in a temperature range of -90 °C ... +250 °C.
    Product number: 1030-3403
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 4 calibration points, in a temperature range of -90 °C ... +250 °C. 

    Product number: 1030-3404
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 5 calibration points, in a temperature range of -90 °C ... +250 °C.
    Product number: 1030-3405
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 6 calibration points, in a temperature range of -90 °C ... +250 °C.

    Product number: 1030-3406