EBI 12-TP451 Enregistreur de validation
EBI 12-TP451
Enregistreur de validation
Réf. produit :
1340-6643
WEEE-Reg.-Nr. DE 29884659
Informations sur le produit
Validation logger for thermal testing of processes with steam sterilizers. The logger is characterized by its highly flexible cable sensors, which enable precise positioning.
With its 3 temperature sensors and the pressure sensor it is ideally suited for measurement in small sterilizers.
The very thin temperature sensors with a diameter of 1.2 mm at the sensor tip enable a very fast response time.
When using the logger in the washer-disinfector, it is strongly recommended to fix the sensors by means of silicone cable ties.
Benefits:
- highly flexible cable probes
- high accuracy
- Realtime data transmission
- fast response time
- sterilizable data logger
Applications:
- Validation logger for Measurement in the steam sterilizer
Datasheet
NEW: Information package "Professional data loggers"
You still need a more comprehensive overview of the possibilities and requirements of the data logger, references to the service, certificates or the suitable software? Then read the comprehensive information package for the food sector or the medical/pharmaceutical sector here.Fiche technique
- Capacité de mémoire
- 4 x 20.064 valeurs mesurées
- Capteur
- Pt 1,000, class A
- Poids
- Env. 120 g
- Précision
- ±0,1 °C (0 °C ... +120 °C) ±0,05 °C (+120 °C ... +140 °C) ±0,1 °C (+140 °C ... +150 °C)
±15 mbar (1 mbar ... 50 mbar), ±10 mbar (50 mbar … 150 mbar), ±10 mbar (2.050 mbar … 2.250 mbar),
±10 mbar (3.000 mbar … 3.250 mbar), ± 15 mbar (3.250 mbar ... 3.500 mbar),
± 0,5 % FS (3.500 mbar ... 4.000 mbar) - Type de protection
- IP 68
- Dimensions
- ø 48 mm x 32 mm
- Résolution
- 0,01 °C 1 mbar
- Certificat
- Certificat d'etallonage d'usine
- Grandeurs de mesure
- Température, pression
- Intervalle de mesure
- 250 ms ... 24 h
- Pile
- Pile bouton lithium, 3,6 V, remplaçable
- Plage de mesure
- Température 0 °C … +150 °C Pression 1 … 4.000 mbar
- Témperature de stockage
- -20 °C ... +70 °C
Accessories
Software & Interfaces
Remplacement des piles & Maintenance
Mallette de transport
Calibration
NEW: Information package "Professional data loggers"
Please fill out the form below and the download will start instantly.
Standards and Directives
• (CE) N° 1935/2004 Matériaux et objets en contact avec des denrées alimentaires• ISO 17665 Sterilization of health care products — Moist heat
• 2014/53/EU Radio Equipment Directive - RED