TFX 430 + TPX 330 Thermométre de précision

Réf. produit : 1340-5439

Thermomètre de référence avec sonde Pt 100 échangeable

  • Pt 100
  • Haute précision
  • Étancheitè IP 67
  • Durée de vie de la pile env. 5 ans
  • Sondes differentes pour applications variables
Poids
Env. 90 g
Précision
±0,05 °C (-50,00 °C … +199,99°C)
±0,4 % of the measurement value for the rest
±0,08 °F (-58 °F … +392 °F)
±0,4 % of the measurement value for the rest
Type de protection
IP67
Dimensions
109 x 54 x 22 mm
Résolution
0.01 °C (-100 °C...+199,99 °C) 0.1 °C for the remaining measuring range
Certificat
Certificat d'etallonage d'usine
Grandeurs de mesure
Température
Intervalle de mesure
1 sec à 15 sec
Pile
Pile lithium 3 V / 1 Ah, Type CR 2477
Plage de mesure
-70 °C...+400 °C
Témperature de stockage
-30 °C...+70 °C
  • Calibration for handhelds of the following products: TFN 5x0 series without probe, TFX 430 with probe Consisting of ISO calibration at 4 standard temperature points that are defined by us. (according to ISO 9001)
    Réf. produit : 1030-2404
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 3 calibration points, in a temperature range of -90 °C ... +250 °C.
    Réf. produit : 1030-3403
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 2 calibration points, in a temperature range of -90 °C ... +250 °C. 
    Réf. produit : 1030-3402
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 1 calibration point, in a temperature range of -90 °C ... +250 °C.
    Réf. produit : 1030-3401
  • Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 4 calibration points, in a temperature range of -90 °C ... +250 °C. 
    Réf. produit : 1030-3404
  • Service d'étalonnage 1030-3405 
    Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 5 calibration points, in a temperature range of -90 °C ... +250 °C.
    Réf. produit : 1030-3405
  • Etalonnage accrédité 1030-3406 
    Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 6 calibration points, in a temperature range of -90 °C ... +250 °C.
    Réf. produit : 1030-3406
  • Etalonnage accrédité 1030-3407 
    Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 7 calibration points, in a temperature range of -90 °C ... +250 °C.
    Réf. produit : 1030-3407
  • Service d'étalonnage 1030-3408 
    Accredited Calibration Service for handhelds of the following product series: TFX incl. probe, TFE incl. probe, TFN incl. probe, TLC 1598, GFX incl. probe, TTX incl. probe Consisting of DIN EN ISO / IEC 17025 (accredited calibration according to DAkkS specifications) Calibration at 8 calibration points, in a temperature range of -90 °C ... +250 °C.
    Réf. produit : 1030-3408
  • TFX Support mural avec 6 pinces de fixation murale, support plastique pour thermomètre TFX
    Réf. produit : 1340-5000
  • Pt 100 Sonde de rechange pour thermométre TFX 430/GFX 460
    Réf. produit : 1341-5437
  • AG 120 Etui en cuir synthétique pour appareils TFX (sans appareil)
    Réf. produit : 1341-0619
  • Sonde remplacemenet Pt 100 pour thermomètre TFX 430/GFX 460
    Réf. produit : 1341-5438
  • Etui de protection pour thermométres Couleurs disponibles: rouge 
    Réf. produit : 1340-5005
  • Câble d'extension pour GFX 460 B, câble en silicone L = 1m
    Réf. produit : 1340-5020
  • Aluminum case (small) for TFN-instruments
    Réf. produit : 1341-3854
  • Grande mallette pour les appareils TFN et plusieurs sondes (sans appareil ni accessoires)
    Réf. produit : 1341-3857