Validation logger for thermal testing of processes with steam sterilizers. The logger is characterized by its bendable metal probes.
The very thin temperature sensors with a diameter of 1.5 mm at the sensor tip enable a very fast response time.
With this logger and the AL 126 Endoscope Flow Control Adapter, regular routine checks in RDG-E are easy to perform.
Benefits:
- bendable metal probe
- high accuracy
- Realtime data transmission
- fast response time
- sterilizable data logger
Applications:
- Validation logger for Measurement in the steam sterilizer, WD and endoscope washer
Datasheet
NEW: Information package "Professional data loggers"
You still need a more comprehensive overview of the possibilities and requirements of the data logger, references to the service, certificates or the suitable software? Then read the comprehensive information package for the food sector or the medical/pharmaceutical sector here.Technical Data
- Data memory
- 2 x 33.440 measurement values
- Weight
- approx. 120 g
- Accuracy
-
±15 mbar (1 mbar ... 49 mbar)
±10 mbar (50 mbar … 150 mbar)
±15 mbar (151 mbar ... 2.049 mbar)
±10 mbar (2.050 mbar … 2.250 mbar)
±15 mbar (2.251 mbar ... 2.999 mbar)
±10 mbar (3.000 mbar … 3.250 mbar)
±15 mbar (3.251 mbar ... 3.499 mbar)
±20 mbar (3.500 mbar ... 4.000 mbar)
- Protection class
- IP68
- Dimensions
- ø 48 mm x 32 mm
- Resolution
- 0,01 °C 1 mbar
- Certificate
- Factory calibration: 0 °C, +60 °C and +134 °C 100 mbar and 3,100 mbar at +25 °C and 3,100 mbar at +134 °C
- Measured variables
- Temperature, pressure
- Intervall
- 250 ms ... 24 h
- Battery
- 3.6 V lithium battery exchangeable
- Measuring range
- Temperature: 0 °C … +150 °C Pressure : 1 … 4.000 mbar
- Storage temperature
- -20 °C ... +70 °C
Accessories
Skip product gallery
Accessories
AL 126
Test adapter for hollow bodies and hoses
for validation in washer disinfector and endoscope washer
Software & Interfaces
Battery replacement & Maintenance
Carrying Case
Calibration
NEW: Information package "Professional data loggers"
Please fill out the form below and the download will start instantly.
Standards and Directives
- ISO 17665 Sterilization of health care products — Moist heat
- ISO 15883 Washer Disinfectors
- 2014/53/EU Radio Equipment Directive - RED
- (CE) N° 1935/2004 Materiales y objetos que entran en contacto con los alimentos