EBI 12-TP237 Data logger for Routine control
Product number:
1340-6658
to measure in WD's and steam sterilizers
The data logger for routine and batch control in the WD and steam sterilizer. The logger is characterized by high accuracy and the hose connection for the pressure sensor.
This data logger is part of the emergency set which we recommend for every reprocessing unit for medical devices in order to be able to continue to collect and store independent measurement data during reprocessing even in the event of a network failure.
Benefits:
- robust data logger
- wireless measurement
- Realtime data transmission
- sterilizable data logger
Applications:
- Validierlogger für die Messung im Dampfsterilisator, RDG, RDG-E
Datasheet
- Data memory
- 2 x 33.440 measurement values
- Sensor
- Pt 1,000, class A
- Weight
- approx. 120 g
- Accuracy
- ±20 mbar
- Protection class
- IP68
- Dimensions
- ø 48 mm x 32 mm - Needle length 20 mm
- Resolution
- 0.01 °C
- Certificate
- Factory Calibration: 0 °C, +60 °C and +134 °C 100 mbar and 3,100 mbar at +25 °C and 3,100 mbar at +134 °C
- Measured variables
- Temperature, pressure
- Intervall
- 250 ms...24 h
- Battery
- 3.6 V Battery battery exchangeable
- Measuring range
- 0 °C...+140 °C. 1 mbar...4000 mbar
- Storage temperature
- -20 °C...+70 °C
-
- Developed for real time monitoring
- AL 112 is a cable with 3 m length
- Antenna placement in the field of the door seal of a sterilizer or washer disinfector
- Antenna steam-tight
- It is possible by a sealing to introduce it in the chamber
Product number: 1340-6007 -
for opening the data logger, e.g. for battery change. The set consists of 2 parts
Product number: 1100-0131 -
Eyelet ring incl. sealing rings for EBI 12 to mount the data loggerProduct number: 1248-0122
-
4-port Interface IF 200
Software Winlog.validation
USB connection
Colored LEDs signaling programming, readout and incorrect development
Includes antenna
Product number: 1340-6068 -
2-port Interface IF 100
Software Winlog.med
USB connection
Colored LEDs signaling programming, readout and incorrect development
Product number: 1340-6064 -
4-port Interface IF 200
Software Winlog.pro
USB connection
Colored LEDs signaling programming,readout and incorrect development
Includes antenna
Product number: 1340-6062 -
1-port Interface IF 150
Software Winlog.med
USB connection Colored
LEDs signaling programming, readout and incorrect development
Product number: 1340-6193 -
USB-connector
Colored LED signals programming,
readout and faulty execution
Including Antenna AL 111
Software Winlog.medProduct number: 1340-6095
-
For EBI 12 + EBI 16 Consisting of 3 batteries, 6 O-rings with grease.Product number: 1100-0118
-
for opening the data logger, e.g. for battery change. The set consists of 2 parts
Product number: 1100-0131 -
Consisting of 3 batteries, 6 O-rings with grease and opening tool EBI 12Product number: 1100-0130
-
For transport of systainers Fixed seat of the systainers on the trolleyProduct number: 1248-0127
-
- Combined
- Modular construction
- Loggers are safely stored
Product number: 1248-0128 -
Especially for validation sets Insert for EBI 12 and InterfaceProduct number: 1248-1100
-
ISO Calibration for pressure- temperature data logger, humidity- and conductivity data logger at 3 standard temperature points and the calibration of the additional measurand of the following product series: EBI 12, EBI 11, EBI 10, EBI 100.Product number: 1030-2223
-
Accredited calibration according to DAkkS guidelines for pressure- temperature data logger, humidity- and conductivity data logger at three temperature points of the following product series: EBI 12, EBI 11, EBI 10, EBI 100.Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.Product number: 1030-3223
-
Accredited calibration according to DAkkS guidelines for pressure- temperature data logger, humidity- and conductivity data logger at four temperature points of the following product series: EBI 12, EBI 11, EBI 10, EBI 100.Consisting of an accedited calibration according to DIN EN ISO / IEC 17025.Product number: 1030-3224
-
Accredited calibration according to DAkkS guidelines for pressure- temperature data logger, humidity- and conductivity data logger at five temperature points.Calibration service for pressure- temperature data logger of the following product series:
EBI 12, EBI 11, EBI 10, EBI 100Consisting of an accedited calibration according to DIN EN ISO / IEC 17025.Product number: 1030-3225 -
Accredited calibration according to DAkkS guidelines for pressure- temperature data logger, humidity- and conductivity data logger at six temperature points of the following product series: EBI 12, EBI 11, EBI 10, EBI 100.Consisting of an accedited calibration according to DIN EN ISO / IEC 17025.Product number: 1030-3226
- (EC) 1935/2004 Materials and articles which come into contact with foodstuffs
- ISO 17665 Sterilization of health care products — Moist heat
- ISO 15883 Washer Disinfectors
- 2014/53/EU Radio Equipment Directive - RED
NEW: Information package "Professional data loggers"
Please fill out the form below and the download will start instantly.