TLC 750 BT Dual Radio Thermometer

for the efficient collection and documentation of measurement data

  • Wireless data transmission via Bluetooth Low Energy 
  • Wireless recharchable battery 
  • Display with backlight for reading in dark environments
  • Display can be upside down for reading from
    both sides

Product number: 1340-5740
Data memory
200 measurement values
Sensor
Thermocouple type T
Weight
Approximately 140 g
Accuracy
Accuracy infrared ±4 °C at -50 °C ... -30.1 °C (±7.2 °F at -58 °F ... -22 °F) ±2.5 °C at -30 °C ... -18.1 °C (±4.5 °F at -22 °F ... -0.4 °F) ±1.5 °C at -18 °C ... -0.1 °C (±2.7 °F at -0.4 °F ... 32 °F) ±1.0 °C at 0 °C ... +65 °C (±1.8 °F at 32 °F ... 149 °F) ±2.0 °C or 2 % at +65 °C ... +250 °C (±3.6 °F at 149 °F ... 482 °F) Accuracy penetration probe ±0.5 °C at -30 °C ... +99.9 °C (±0.9 °F at -22 °F ... 212 °F) ±1 °C (±2 °F) or 1 % for the remaining measurement range (whichever is larger)
Protection class
IP65
Dimensions
169.5 x 44x23mm (without probe), needle length=100 mm
Resolution
0.1 °C / 0.2 °F
Certificate
Factory calibration certificate
Measured variables
Temperature
Battery
Recharchable lithium polymer battery 3.7 V
Measuring range
-50 °C ... +250 °C (-58 °F ... 482 °F)
Storage temperature
-30 °C ... +70 °C (-40 °F ... 158 °F)
  • Punching pin for drilling hole in deep-frozen food to take core temperature reading
    Product number:: 1341-3834
  • ISO Calibration for handhelds at 3 standard temperature point of product series: 
    TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.

    Product number:: 1030-2403
  • ISO Calibration for handhelds at 4 standard temperature point of product series: 
    TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.

    Product number:: 1030-2404
  • Accredited calibration according to DAkkS guidelinesfor handhelds at three points of product series: 
    TFX, TFE, TFN, TLC, GFX, TTX, TFH.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.  
    Product number:: 1030-3403
  • Accredited calibration according to DAkkS guidelines for handhelds at four points.
    Calibration service for handhelds of product series: TFX, TFE, TFN, TLC, GFX, TTX, TFH.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.

    Product number:: 1030-3404
  • Accredited calibration according to DAkkS guidelines for handhelds at five points of product series: 
    TFX, TFE, TFN, TLC, GFX, TTX, TFH.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.

    Product number:: 1030-3405
  • Accredited calibration according to DAkkS guidelinesfor handhelds at six points.
    Calibration service for handhelds of product series: TFX, TFE, TFN, TLC, GFX, TTX, TFH.
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.

    Product number:: 1030-3406
  • Accredited calibration according to DAkkS guidelines for handhelds at seven points.
    Calibration service for handhelds of product series: TFX, TFE, TFN, TLC, GFX, TTX, TFH
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025

    Product number:: 1030-3407
  • Accredited calibration according to DAkkS guidelines for handhelds at eight points. 
    Calibration service for handhelds of product series: TFX, TFE, TFN, TLC, GFX, TTX, TFH
    Consisting of an accredited calibration according to DIN EN ISO / IEC 17025

    Product number:: 1030-3408