TTX 110 Core Thermometer Thermocouple Type T
Thermocouple thermometer with fixed probe
• Fast measurements, high accuracy
• HACCP
• Robust and impact resistant
• Replaceable battery
• HACCP
• Robust and impact resistant
• Replaceable battery
Product number:
1340-5110
- Weight
- approx. 40 g
- Accuracy
- ± 0.8 °C or ± 0.8 % whichever is greater
- Protection class
- IP55
- Dimensions
- 90 x 42 x 17 mm
- Resolution
- 0.1 °C from -60 °C...+199 °C otherwise 1°C
- Certificate
- Factory calibration certificate
- Measured variables
- temperature
- Battery
- Lithium 3 V , type CR 2450
- Measuring range
- -50 °C...+350 °C
- Storage temperature
- -30 °C...+70 °C
-
Punching pin for drilling hole in deep-frozen food to take core temperature readingProduct number:: 1341-3834
-
ISO Calibration for handhelds at 3 standard temperature point of product series:
TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.Product number:: 1030-2403 -
ISO Calibration for handhelds at 4 standard temperature point of product series:
TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.Product number:: 1030-2404 -
ISO Calibration for handhelds at 5 standard temperature point of product series:
TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.Product number:: 1030-2405 -
ISO Calibration for handhelds at 6 standard temperature point of product series:
TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.Product number:: 1030-2406 -
ISO Calibration for handhelds at 7 standard temperature point of product series:
TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.Product number:: 1030-2407 -
ISO Calibration for handhelds at 8 standard temperature point of product series:
TFX, TFE, TFN, TLC, TFI, GFX, TTX, TFH, FOM, CT, PHT, VAM.Product number:: 1030-2408 -
Accredited calibration according to DAkkS guidelinesfor handhelds at three points of product series:
TFX, TFE, TFN, TLC, GFX, TTX, TFH.Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.Product number:: 1030-3403 -
Accredited calibration according to DAkkS guidelines for handhelds at four points.Calibration service for handhelds of product series: TFX, TFE, TFN, TLC, GFX, TTX, TFH.Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.Product number:: 1030-3404
-
Accredited calibration according to DAkkS guidelines for handhelds at five points of product series:
TFX, TFE, TFN, TLC, GFX, TTX, TFH.Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.Product number:: 1030-3405 -
Accredited calibration according to DAkkS guidelinesfor handhelds at six points.Calibration service for handhelds of product series: TFX, TFE, TFN, TLC, GFX, TTX, TFH.Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.Product number:: 1030-3406
-
Accredited calibration according to DAkkS guidelines for handhelds at seven points.Calibration service for handhelds of product series: TFX, TFE, TFN, TLC, GFX, TTX, TFHConsisting of an accredited calibration according to DIN EN ISO / IEC 17025Product number:: 1030-3407
-
Accredited calibration according to DAkkS guidelines for handhelds at eight points.Calibration service for handhelds of product series: TFX, TFE, TFN, TLC, GFX, TTX, TFHConsisting of an accredited calibration according to DIN EN ISO / IEC 17025Product number:: 1030-3408