EBI 12-TP222 Validation logger to measure in autoclaves
Easy to place the bendable metal probe for temperature measurement
Validation logger for thermal testing of processes with steam sterilizers. The logger is characterized by its bendable metal probes.
The very thin temperature sensors with a diameter of 1.5 mm at the sensor tip enable a very fast response time.
With this logger and the AL 126 Endoscope Flow Control Adapter, regular routine checks in RDG-E are easy to perform.
Benefits:
- bendable metal probe
- high accuracy
- Realtime data transmission
- fast response time
- sterilizable data logger
Applications:
- Validation logger for Measurement in the steam sterilizer, WD and endoscope washer
Datasheet
- Data memory
- 2 x 33.440 valores
- Weight
- aprox. 120 g
- Accuracy
- ±0,1 °C (0 °C ... +120 °C)
±0,05 °C (+120 °C ... +140 °C)
±0,1 °C (+140 °C ... +150 °C)
±15 mbar (1 mbar ... 50 mbar), ±10 mbar (50 mbar … 150 mbar), ±10 mbar (2.050 mbar … 2.250 mbar),
±10 mbar (3.000 mbar … 3.250 mbar), ± 15 mbar (3.250 mbar ... 3.500 mbar),
± 0,5 % FS (3.500 mbar ... 4.000 mbar) - Protection class
- IP68
- Dimensions
- ø 48 mm x 32 mm
- Resolution
- 0,01 °C 1 mbar
- Certificate
- Certificado de calibración de fábrica
- Measured variables
- Temperatura, presión
- Intervall
- 250 ms ... 24 h
- Battery
- 3.6 V lithium battery exchangeable
- Measuring range
- Temperatura: 0 °C … +150 °C Presión: 1 … 4.000 mbar
- Storage temperature
- -20 °C ... +70 °C
-
- Developed for real time monitoring
- AL 112 is a cable with 3 m length
- Antenna placement in the field of the door seal of a sterilizer or washer disinfector
- Antenna steam-tight
- It is possible by a sealing to introduce it in the chamber
Product number: 1340-6007 -
The test adapter offers a simple solution in connection with cleaning indicator (test soil) to perform a routine test in relation to cleaning performance as well as performance qualification during validation processes according to national standards. In addition to AL 126 we recommend also to use a combination of pressure and temperature logger.
The set contains:
• Test adapter
• Luer-Lock connection to connect a
pressure logger
• 2 x Tube adapter 4 mm
• 1 x clamp connection 1.5 mm
• 2 x O-rings for fitting test soilProduct number: 1248-0126 -
for opening the data logger, e.g. for battery change. The set consists of 2 parts
Product number: 1100-0131 -
Eyelet ring incl. sealing rings for EBI 12 to mount the data loggerProduct number: 1248-0122
-
AL 285 Logger Check In combination with the software Winlog.validation version >= 3.62 the AL 285 offers you a simple, on site functional check of the measuring channels.Product number: 1248-0285
-
4-port Interface IF 200
Software Winlog.validation
USB connection
Colored LEDs signaling programming, readout and incorrect development
Includes antenna
Product number: 1340-6068 -
2-port Interface IF 100
Software Winlog.med
USB connection
Colored LEDs signaling programming, readout and incorrect development
Product number: 1340-6064 -
4-port Interface IF 200
Software Winlog.pro
USB connection
Colored LEDs signaling programming,readout and incorrect development
Includes antenna
Product number: 1340-6062 -
USB-connector
Colored LED signals programming,
readout and faulty execution
Including Antenna AL 111
Software Winlog.medProduct number: 1340-6095 -
1-port Interface IF 150
Software Winlog.med
USB connection Colored
LEDs signaling programming, readout and incorrect development
Product number: 1340-6193
-
for opening the data logger, e.g. for battery change. The set consists of 2 parts
Product number: 1100-0131 -
For EBI 12 + EBI 16 Consisting of 3 batteries, 6 O-rings with grease.Product number: 1100-0118
-
Consisting of 3 batteries, 6 O-rings with grease and opening tool EBI 12Product number: 1100-0130
-
For transport of systainers Fixed seat of the systainers on the trolleyProduct number: 1248-0127
-
Especially for validation sets Insert for EBI 12 and InterfaceProduct number: 1248-1100
-
- Combined
- Modular construction
- Loggers are safely stored
Product number: 1248-0128
-
ISO Calibration for pressure- temperature data logger, humidity- and conductivity data logger at 3 standard temperature points and the calibration of the additional measurand of the following product series: EBI 12, EBI 11, EBI 10, EBI 100.Product number: 1030-2223
-
Accredited calibration according to DAkkS guidelines for pressure- temperature data logger, humidity- and conductivity data logger at three temperature points of the following product series: EBI 12, EBI 11, EBI 10, EBI 100.Consisting of an accredited calibration according to DIN EN ISO / IEC 17025.Product number: 1030-3223
-
Accredited calibration according to DAkkS guidelines for pressure- temperature data logger, humidity- and conductivity data logger at four temperature points of the following product series: EBI 12, EBI 11, EBI 10, EBI 100.Consisting of an accedited calibration according to DIN EN ISO / IEC 17025.Product number: 1030-3224
-
Accredited calibration according to DAkkS guidelines for pressure- temperature data logger, humidity- and conductivity data logger at five temperature points.Calibration service for pressure- temperature data logger of the following product series:
EBI 12, EBI 11, EBI 10, EBI 100Consisting of an accedited calibration according to DIN EN ISO / IEC 17025.Product number: 1030-3225 -
Accredited calibration according to DAkkS guidelines for pressure- temperature data logger, humidity- and conductivity data logger at six temperature points of the following product series: EBI 12, EBI 11, EBI 10, EBI 100.Consisting of an accedited calibration according to DIN EN ISO / IEC 17025.Product number: 1030-3226
- ISO 17665 Sterilization of health care products — Moist heat
- ISO 15883 Washer Disinfectors
- 2014/53/EU Radio Equipment Directive - RED
- (CE) N° 1935/2004 Materiales y objetos que entran en contacto con los alimentos